§ 12-181. Minimum insulation R-values.
(a)
There shall be maintained the following minimum insulation R-values for all insulation installation:
(1)
Attic floor if attic is not used, roof if attic is used: R-30.
(2)
Exterior side walls: R-11.
(3)
Floor over unheated basement or crawl space: R-19.
(4)
Wall of heated basement: R-8.
(5)
Perimeter of house on slab, down to frost line or at least two feet down from slab: R-8.
(b)
The fee for installation of insulation for residential homes shall be as shown in the village fee schedule per $1,000.00 estimated cost of installation with a minimum fee of $25.00.